Warning: ini_set(): A session is active. You cannot change the session module's ini settings at this time in /home/zealp1/public_html/lib/pkp/classes/session/SessionManager.inc.php on line 69

Warning: Cannot modify header information - headers already sent by (output started at /home/zealp1/public_html/lib/pkp/classes/session/SessionManager.inc.php:69) in /home/zealp1/public_html/plugins/generic/citationStyleLanguage/CitationStyleLanguagePlugin.inc.php on line 478

Warning: Cannot modify header information - headers already sent by (output started at /home/zealp1/public_html/lib/pkp/classes/session/SessionManager.inc.php:69) in /home/zealp1/public_html/plugins/generic/citationStyleLanguage/CitationStyleLanguagePlugin.inc.php on line 479
TY - JOUR AU - Silva, T.I. AU - Ferreira, M.O.A. AU - Nascimento, J.P.L. AU - Pietro, L.R. AU - Neto, L.A.R. Cintra AU - Moreira, H.C. AU - Pereira, L.V. AU - Leite, N.B. AU - Gelamo, R.V. AU - Moreto, J. A. PY - 2022/12/14 Y2 - 2025/08/20 TI - Development of a Low-Cost Ball-on-Flat Linear Reciprocating Apparatus: Test Validation Using Ti-6Al-4V and Ti-6Al-4V/Nb2O5 Coatings JF - Journal of Material Science and Technology Research JA - J. Mater. Sci. Technol. Res. VL - 9 IS - 1 SE - Articles DO - 10.31875/2410-4701.2022.09.05 UR - https://www.zealpress.com/index.php/jmstr/article/view/444 SP - 43-52 AB - <p class="p1"><span class="s1"><strong>Abstract: </strong></span>This work aims to propose the development of a low-cost ball-on-flat linear reciprocating apparatus that can have the same attributes of extremely expensive equipment available on the market. For this purpose, the device was constructed following the recommendations of the ASTM G133 standard. The device’s validation was performed trough a comparative study between the ASTM G133 standard and 3D profilometry technique by using Ti-6Al-4V and Ti-6Al-4V/Nb2O5 specimens. The results obtained in the present work were very motivating by showing it was possible to obtain the wear properties with reproducibility through the equipment constructed. The wear tests showed that the functionalization of the Ti-6Al-4V alloy with Nb<sub>2</sub>O<sub>5</sub> coatings increased the wear resistance of the biomaterial, reducing the wear volume about 80.1 % when compared to the base material. Finally, this work demonstrated (i) the effectiveness and reproducibility of the device built to carry out microwear tests, (ii) the increase in resistance to the mechanical wear process conferred by the Nb<sub>2</sub>O<sub>5 </sub>film on the Ti-6Al-4V alloy and (iii) the powerful impact of the 3D profilometry technique when compared to the ASTM G133 standard for wear volume determination.</p> ER -